PF2M725S-C6-B: Precise Sensing, Reliable Protection! Thermal Flow Switch Empowers Fluid System Safety Monitoring
2025-10-16
In systems requiring precise monitoring of minimal flow rates or high response speeds, such as cooling or lubrication systems, mechanical flow switches face limitations like low accuracy and significant pressure drop. The PF2M725S-C6-B thermal (thermal dispersion) flow switch utilizes a sensing principle that involves no moving parts, enabling sensitive and reliable detection of fluid flow velocity. It is the ideal choice for protecting critical equipment.Core Product AdvantagesHigh-Precision Thermal DetectionOperates on the thermal dispersion principle, detecting flow velocity by measuring the rate at which heat is carried away by the fluid. With no moving parts, it offers high accuracy (typically ±5% FS), long service life, and exceptional reliability.Minimal Flow DetectionHighly sensitive to very low flow velocities (capable of detecting velocities as low as 0.1 m/s), effectively identifying minimal flow or no-flow conditions within pipes.Negligible Pressure Drop DesignThe sensor probe inserts directly into the flow path, creating almost no pressure loss and avoiding any impact on normal system operation.Fast ResponseFeatures short response times (typically < 2 seconds), enabling prompt signal output to effectively prevent equipment dry-running or insufficient cooling.Multiple Outputs and DisplayProvides relay or transistor (NPN/PNP) switch outputs. Some models include LED indicators for clear visual feedback of the flow status.Typical Application ScenariosEquipment Protection: Monitors coolant or lubricant flow; triggers alarms or shutdowns during insufficient flow to prevent equipment overheating or wear (e.g., laser equipment, spindle cooling).Pump Dry-Run Protection: Detects pump operational status to prevent damage from dry-running.Process Control: Activates subsequent equipment actions based on flow signals, such as initiating filter system backwashing.Energy Management: Monitors water flow in HVAC systems for coordinated system optimization.Technical Parameters (Typical Values)Port Size: G1/2″ or NPT 1/2 (725 may indicate port code)Flow Setting Range: e.g., 2~25 L/min (water, confirm based on model)Output Signal: SPDT relay / Transistor outputSupply Voltage: DC24V or AC/DC wide voltage (C6 may indicate voltage code)Pressure Rating: 1.0 MPa or higherSummaryThe PF2M725S-C6-B thermal flow switch acts as a ”Sensitive Sentinel” in the realm of minimal flow monitoring. With its high precision, high reliability, and negligible pressure drop, it provides effective early warning and protection for fluid systems in crucial equipment. It is particularly suited for low-flow, high-reliability applications where mechanical switches fall short.Choosing the PF2M725S-C6-B means selecting a precise, reliable, and efficient flow monitoring solution!
| PF2MC7102-04-F |
| PF2M750-01-E-M |
| PF2M721W-C8-AW-MV |
| PF2M750-C6-CW |
| PF2M710S-C6-E |
| PF2M710S-C4-DW-MV |
| PF2M721-F2-C |
| PF2M721-02-F |
| PF2M750-C6-A |
| PF2M710-C6-DW-MT |
| PF2M750S-01-B-S |
| PF2M711-C8-A-M |
| PF2M750S-01-E |
| PF2M721-02-B-M |
| PF2M701-01-D-R |
| PF2M711-C8-A-R |
| PF2M721-C8-D-R |
| PF2MC7501-04-D-MR |
| PF2MC7202-06-D-M-X108 |
| PF2M721-C8-A-M |
| PF2M750S-01-C-M |
| PF2M721S-02-C-S |
| PF2M711S-02-A |
| PF2MC7202-F06-D-MR |
| PF2M721-02-D |
| PF2MC7501-04-D-R |
| PF2M725-C6-C-RA |
| PF2M721S-C8-FN |