Description
Material information LABS containing materials includedRoHs compliant
Nominal voltage logic supply DC [V] 24
Nominal operating voltage DC [V] 24
Nominal current logic supply [A] 0,15
Permitted range logic voltage ?I 20 %
Power input logic supply without parking brake [A] 0,20
Short circuit resistance Yes, exception: Contact C1/C2
Current carrying capacity at 40??C [A] 0,2
Fuse (short circuit) no
Design digital output Potential free signal contact3 secure, 2-channel semi/conductor outputs
Quantity digital logic inputs 10
Digital outputs, switching logic Halbleiterausg?nge: parametrierbar PNP (plusschaltend) 2-kanalig ?quivalent / antivalent
Dimensions W x L x H 112.2 mm x 99.1 mm x 28.7 mm
LED display product specific Error (red)Normal mode (Green)Safe conditions (yellow)
Safety function Safe switched off torque (STO)Safe limited speed (SLS)Safe braking controls (SBC)Safe operating stop (SOS)Safe stop 1 (SS1)Safe stop 2 (SS2)Safe speed range (SSR)Safe speed monitoring (SSM)
Probability of Failure per Hour in [1/h]. 9.5e-009
Proof test interval [A] 20
Hardware error tolerance 1
SFF Safe Failure Fraction [%] 99,5
Certified for safety function to ISO 13849 and IEC 61508 (SIL) Product can be inserted into SRP/CS to SIL 3 High Demand
Safety Integrity Level (SIL) Safe switched off torque (STO) / SIL 3Safe braking controls (SBC) / SIL 3Safe limited speed (SLS) / SIL 3Safe operating stop (SOS) / SIL 3Safe stop 1 (SS1) / SIL 3Safe stop 2 (SS2) / SIL 3Safe speed monitoring (SSM) / SIL 3Safe speed range (SSR) / SIL 3
Performance Level (PL) Sicher abgeschaltetes Moment (STO) / Kategorie 4, Performance Level eSichere Bremsenansteuerung (SBC) / Kategorie 4, Performance Level eSicher begrenzte Geschwindigkeit (SLS) / Kategorie 3, Performance Level eSicherer Betriebshalt (SOS) / Kategorie 3, Performance Level eSicherer Stopp 1 (SS1) / Kategorie 3, Performance Level eSicherer Stopp 2 (SS2) / Kategorie 3, Performance Level eSichere Geschwindigkeits??berwachung (SSM) / Kategorie 3, Performance Level eSicherer Geschwindigkeitsbereich (SSR) / Kategorie 3, Performance Level e
Diagnose degree of coverage [%] 97,5
Certified for safety function to ISO 13849 (PL) Product can be inserted into SRP/CS to category 4, PL e
Permission T??V
CE certificate (see declaration of conformity) to EU EMC directiveto EU machinery directive
Certified awarding point 01/205/5165.02/19T??V Rheinland
Bearing temperature [??C] -25 to 55
Relative humidity 5 – 90 %Not condensing
Protection category IP20In mounted condition
ambient temperature [??C] 0 to 40
Product weight [g] 220
Fastening type Plug-in module for CMMP-AS… -M3
installation position arbitrary
Wire ends Wire end sleeve
Connection cross-section [mm2] 0.25 to 0.5
Electrical connection Screw clampPlug straight
Display LED green / yellow / red
Operating element Dip switch
Logic input specification IEC 61131-2, Typ 3
Properties logic inputs 4 sichere, 2-kanalige Eing?nge?quivalent / antivalent schaltendTestimpulse konfigurierbarFunktion konfigurierbar6 sichere, 1-kanalige Eing?ngeTestimpulse konfigurierbar
Work area logic input [V] 13 to 28.8
Max. nominal input current [A] 0,015
Debounce time inputs [ms] 0,3
Current carrying capacity per output [mA] 50
Max. current digital logic outputs [mA] 50
Output fuses Short and cross-connection monitoring
Minimum cycle time [ms] 2
Parameterising Via SafetyTool
Reviews