Description
		 Permission		  c CSA us (OL)
					 Line designation		  Without sign holder
					 Product weight [g]		  100
					 Electrical connection 1, function		  Field device screen
					 Electrical connection 1, design		  Angular
					 Electrical connection 1, connection type		  socket / container / ??.
					 Electrical connection 1, cable output		  Angled
					 Electrical connection 1, connection technology		  Wiring diagram Form B acc. to industry standard 11 mm
					 Electrical connection 1, number of pins / wires		  3
					 Electrical connection 1, occupied pin / wire		  3
					 Electrical connection 1, fastening type		  on solenoid valve with central screw M3
					 Electrical connection 2, function		  Control screen
					 Electrical connection 2, design		  round
					 Electrical connection 2, connection type		  Plug
					 Electrical connection 2, cable output		  Angled
					 Electrical connection 2, connection technology		  M12x1 A coded to EN 61076-2-101
					 Electrical connection 2, number of pins / wires		  5
					 Electrical connection 2, occupied pin / wire		  3
					 Electrical connection 2, fastening type		  Screw lock with hexagonal SW13
					 Operating voltage range DC [V]		  18 to 30
					 Nominal operating voltage DC [V]		  24
					 Operating voltage range AC [V]		  18 to 30
					 Nominal operating voltage AC [V]		  24
					 Current carrying capacity at 40??C [A]		  4
					 Surge voltage strength [kV]		  0,8
					 Protection line connection		  Available
					 Cable length [MTR]		  0,6
					 Line properties		  Standard
					 Test conditions line		  Test conditions on request
					 Cable diameter [mm]		  5,9
					 Tolerance cable diameter		  ?I 0,3 mm
					 Cable set up		  3×0,75
					 Protection category		  IP67
					 Information about protection category		  In mounted condition
					 ambient temperature [??C]		  -25 to 80
					 Ambient temperature for moving cable placements [??C]		  -25 to 80
					 CE certificate (see declaration of conformity)		  nach EU-RoHS-RL
					 Material information		  LABS containing materials includedRoHs compliant
					 Degree of contamination		  3
					 Corrosion resistant class KBK		  2 – moderate corrosion stress
					 Cable sleeve material		  TPE-U(PUR)
					 Cable shield colour		   Grey
					 Housing material		  TPE-U(PUR)
					 Housing colour		   black
					 Locking nut material		  nickel-platedZinc pressure cast
					 Insulation sleeve material		  PP
					 Switching status indicator		  LED yellow
					 Additional functions		  protection circuit		 					 	 	 	 	 