Description
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Information about operating and control medium Oiled operation not possible
Construction set up Mechanical sequence counter with pneumatic actuator
Reset mode Manual button or pneumatic signal
Display 5 digits
Actuator pressure drop 0,2 ?I 0,1 bar
Reset pressure drop 0,15 ?I 0,1 bar
Reaction pressure actuator 0,6 ?I 0,2 bar
Operating pressure [bar] 2 to 8
Min. switch reset pressure [bar] 2
Min. impulse duration actuator [ms] 10
Min. impulse duration reset [ms] 180
Min. pause duration actuator [ms] 15
Min. pause duration reset [ms] 50
ambient temperature [??C] 0 to 60
Product weight [g] 150
Fastening type Front panel integration
Pneumatic connection M5