Description
Permission RCM markc UL us – Listed (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directiveacc. to EU-RoHS Directive
KC-mark KC-EMV
Certified awarding point UL E322346
Material information RoHs compliant
Measured parameter Mass flowVolume flow rate
Flow direction Uni-directional
Measurement principle Thermic
Measurement process Heat Transfer
Flow measurement range starting value [l/min] 2,000
Flow measurement range end value [l/min] 100,0
Operating pressure [bar] -0.9 to 10
Operating medium Druckluft nach ISO 8573-1:2010 [6:4:4]StickstoffArgon
Medium temperature [??C] 0 to 50
ambient temperature [??C] 0 to 50
Nominal temperature [??C] 23
Accuracy flow value ?I (2% o.m.v. + 1% FS)
Repeatability null point in ?I %FS [%FS] 0,2
Repeatability clamp in ?I %FS [%FS] 0,8
Temperature coefficient clamp in ?I %FS/K type 0,15%FS/K
Pressure dependency clamp in ?I %FS/bar [%FS/b.] 1
Control output 2 x PNP or 2 x NPN switchable
Switch function Window comparatorThreshold comparatorAuto difference monitoring
Switching element function Opener/closer switchable
Max. output current [mA] 100
Analogue output 0 – 10 V4 – 20 mA1 – 5 V
Flow characteristic curve starting value [l/min] 0
Flow characteristic curve end value [l/min] 100,0
Max. load resistance current output [Ohm] 500
Min. load resistance voltage output [kOhm] 20
Short circuit resistance yes
Overload resistant Available
Report IO-Link
IO-Link, report Device V 1.1
IO-Link, profile Smart sensor profile
IO-Link, function classes Teach channelDiagnosisIdentificationBinary data channel (BDC)Process data variables (PDV)
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, SIO mode support yes
IO-Link, port type A
IO-Link, process data width IN 3 Bytes
IO-Link, process data contents IN 1 bit BDC (Volume monitoring)14 bit PDV (Flow measurement)2 bit BDC (Flow monitoring)
IO-Link, service data unit IN 32 bit Volumen-/Massemesswert
IO-Link, minimum cycle time 4 ms
IO-Link, data memory needed [Byte] < 0,5 kB
Operating voltage range DC [V] 22 to 26
Empty run current [mA] <= 25 mA
Reverse polarity protection for all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connection technology M8x1 A coded to EN 61076-2-104
Electrical connection 1, number of pins / wires 4
Fastening type With Accessories
installation position arbitrary
Pneumatic connection For hose exterior diameter 8 mm
Pneumatic connection, connection outlet straight
Product weight [g] 60
Housing material PA reinforced
From medium contacting materials NBRhigh-alloyed stainless steelPA reinforcedAlu wrought alloy, anodisedEpoxy resinSiliconSilicon nitride
Display type Illuminating LCD Multiple
Presentable unit(s) gg/minll/minscftscft/hscft/min
Setting options IO-LinkTeach-In??ber Display und Tasten
Tamper-proof fuse IO-LinkPIN code
Protection category IP40
Pressure drop [mbar] 15
Protection class III
Corrosion resistant class KBK 2 - moderate corrosion stress
Reviews