SFAW-32T-S13-E-PNLK-PNVBA-M12

$588.24

Flow Sensor is a pneumatic component launched by FESTO, which is widely used in the field of industrial automation. Its product quality has been at the leading level in the industry and won the trust and praise of many customers .

Model:SFAW-32T-S13-E-PNLK-PNVBA-M12

FESTO Order Number:8036880

SKU: SFAW-32T-S13-E-PNLK-PNVBA-M12 Category: Tag:

Description

Permission RCM markc UL us – Listed (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directiveacc. to EU-RoHS Directive
KC-mark KC-EMV
Material information RoHs compliant
Measured parameter flowtemperature
Flow direction P1 -> P2Uni-directional
Measurement process temperature: PT1000Flow: Vortex
Flow measurement range starting value [l/min] 1,8
Flow measurement range end value [l/min] 32
Operating pressure [bar] 0 to 12
Information about operating pressure max. 12 bar at 40??Cmax. 6 bar at 100??C
Operating medium Fluid mediaNeutral liquidsWater
Information about operating and control medium Media compatibility to the media contacting materials must be guaranteed
Medium temperature [??C] 0 to 90
ambient temperature [??C] 0 to 50
Nominal temperature [??C] 23
Accuracy flow value ?I2 %FS for flow <= 50 %FS?I 3 % o.m.v. for flow >= 50 %FS
Accuracy temperature in ?I ??C [??C] 2
Repeatability flow value < ?I0.5 %FS for flow <= 50 %FS< ?I1 % o.m.v. for flow >= 50 %FS
Temperature coefficient clamp in ?I %FS/K type ?I0,05%FS/K
Control output 2 x PNP or 2 x NPN switchable
Switch function Window comparatorThreshold comparatorFreely programmable
Switching element function Opener/closer switchable
Max. output current [mA] 100
Analogue output 0 – 10 V4 – 20 mA1 – 5 V
Flow characteristic curve starting value [l/min] 0
Flow characteristic curve end value [l/min] 32
Max. load resistance current output [Ohm] 500
Min. load resistance voltage output [kOhm] 15
Short circuit resistance yes
Overload resistant Available
Report IO-Link
IO-Link, report Device V 1.1
IO-Link, profile Smart sensor profile
IO-Link, function classes Teach channelDiagnosisIdentificationBinary data channel (BDC)Process data variables (PDV)
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, SIO mode support yes
IO-Link, port type A
IO-Link, process data width OUT 0 Bytes
IO-Link, process data width IN 5 Bytes
IO-Link, process data contents IN 1 bit BDC (volume monitoring)14 bit PDV (flow measurement)1 bit BDC (temperature monitoring)14 bit PDV (temperature measurement)2 bit BDC (flow measurement)
IO-Link, service data unit IN 32 bit Volumenmesswert
IO-Link, minimum cycle time 5 ms
IO-Link, data memory needed [Byte] 500
Operating voltage range DC [V] 18 to 30
Reverse polarity protection for all electrical connections
Electrical connection M12x15 pinPlug straightA-coded
Max. line length 30 m20 m For OK link operation
installation position arbitrary
Fluid connection Hose screw connection 13 mm
Product weight [g] 300
Housing material PA reinforced
From medium contacting materials EPDM (perox.)ETFEstainless steelPA6T/6I reinforced
Presentable unit(s) US galUS gal/mincftcft/minll/hl/minm3??C??F
Protection category IP65
Corrosion resistant class KBK 3 – severe corrosion stress
Temperature measurement range stating value [??C] 0
Temperature measurement range end value [??C] 90
Temperature characteristic curve starting value [??C] 0
Temperature characteristic curve end value [??C] 100

Reviews

There are no reviews yet.

Be the first to review “SFAW-32T-S13-E-PNLK-PNVBA-M12”