Description
Design Angular
Based on standard EN 60947-5-6VDI/VDE 3845
Permission RCM markc UL us (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directiveacc. to EU Ex protection Directive (ATEX)acc. to EU-RoHS Directive
Material information LABS containing materials includedRoHs compliant
Measurement principle Inductive
ambient temperature [??C] -25 to 100
Control output NAMUR
Switching element function NC contact
Max. switching frequency [Hz] 3.000
Max. output current DC [mA] 3
Operating voltage range DC [V] 8,2
Electrical connection: input Spring tension clamp
Electrical connection: outlet Spring tension clamp
installation position arbitrary
Product weight [g] 170
Housing material PBT
Screws material High-alloyed stainless steels
Switching status indicator LED yellow
Status display LED yellow = Valve switching status
Bearing temperature [??C] -40 to 100
Protection category IP67
Shock resistance Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Oscillation strength Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Degree of contamination 3
Short circuit resistance yes
Reverse polarity protection for all electrical connections
ATEX gas category II 1G
Ex ignition protection type gas Ex ia IIC T6…T1 Ga
Ex protection approval outside of the EU EPL Ga (IEC-EX)
Ex ambient temperature see ATEX Certificatesee IECEx Certificate
Effective inductivity 100 ??H
Effective capacity 100 nF
Max. input parameter intrinsically safe circuit see ATEX Certificatesee IECEx Certificate
Certified awarding point IECEx TUN 18.0003XT??V 16 ATEX 174269 X
Safety Integrity Level (SIL) SIL 2
Lockable conductor nominal cross-section [mm2] 0.2 to 2.5
Cable screwing M12x1,5M20x1,5
Reviews
There are no reviews yet.