VOFA-L26-T32C-M-G14-1C1-ANP

$966.78

Control Block is a pneumatic component launched by FESTO, which is widely used in the field of industrial automation. Its product quality has been at the leading level in the industry and won the trust and praise of many customers .

Model:VOFA-L26-T32C-M-G14-1C1-ANP

FESTO Order Number:574012

SKU: VOFA-L26-T32C-M-G14-1C1-ANP Category: Tag:

Description

Valve function 3/2 closed monostable
Actuation type Electrical
Build.width [mm] 65
Normal nominal flow [l/min] 1.050
Operating pressure [bar] 3 to 10
Construction set up Piston pusher
Reset mode Mechanical spring
Protection category IP65NEMA 4
Permission c UL us – Recognized (OL)
KC-mark KC-EMV
CE certificate (see declaration of conformity) to EU EMC directiveto EU machinery directive
Certified awarding point UL MH19482
Exhaust function Can be throttled
Sealing principle Soft
installation position arbitrary
Complies to standard EN 60947-5-2
Hand assist actuation none
Control type pilot operated
Control air supply Internal
Flow direction Not reversible
Measurement principle Inductive
??berdeckung positive ??berdeckung
Reverse polarity protection sensor for all electrical connections
Safety function VentingManipulation / start up protection
Performance Level (PL) Manipulation safety, protection against unexpected start up to category 4 performance level eVenting / to category 4 PLe
Information about force dynamic sampling Switching frequency at least 1x per week
Signal condition display With Accessories
Switching position query Idle position with sensor
Noise status indicator LED
Control pressure [bar] 3 to 10
Shifting time off [ms] 54
Shifting time on [ms] 24
Valve – sensor switching time on [ms] 58
Valve – sensor switching time off [ms] 11
Power-on time 100 %
Max. positive test impulse at 0 signal [??s] 1.000
Max. negative test impulse for 1 signal [??s] 800
Control output NPN
Coil characteristic value 24 V DC: 1,8 W
Permitted voltage oscillations -15 % / +10 %
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Information about operating and control medium Oiled operation possible (required in further operations)
Oscillation strength Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistance Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistant class KBK 0 – No corrosion stressing
Max. magnetic error field 60 mT
Medium temperature [??C] -5 to 50
Sound level [dB(A)] 85
Protect against direct and indirect contact Schutzklasse nach EN60950/IEC 950Funktionskleinspannung mit sicherer Trennung (PELV)
control medium Compressed air to ISO 8573-1:2010 [7:4:4]
ambient temperature [??C] -5 to 50
Nominal usage height above normal null 1000 m to VDE 0580
Product weight [g] 1.134
Operating voltage range DC sensor [V] 10 to 30
Short circuit resistance sensor Cycling
Empty run sensor [mA] <= 10 mA Max. output current sensor [mA] 200 Max. switching frequency sensor [Hz] 5.000 Residual ripple sensor ?I 10 % Sensor voltage drop [V] <= 2 V Electrical connection Wiring diagram Form C acc. to EN 175301-803without protective earthing conductoracc. to EN 175301-803 Sensor connection M8x13 pinPlug Fastening type With throughway bores Pneumatic connection 1 G1/4 Pneumatic connection 2 G1/4 Pneumatic connection 3 G1/4 Material information RoHs compliant Seals material FKMHNBRNBR Housing material PAAluminium die casting Screws material Steelzinc plating Switching element function NC contact Vacuum capable no Normal flow Venting 6>0 bar [l/min] 2.650
Venting flow for a valve in case of error [l/min] 1.050