ISO 8573-1 Compressed Air Quality Classes Explained: What [1:4:1] Means and How to Reach It
2026-11-16Machine specifications, filter data sheets and dryer brochures often quote compressed air purity as a short code such as “ISO 8573-1:2010 [1:4:1]” or “7.4.4”. If you are writing a machine specification, answering a customer audit or trying to work out which filters a line actually needs, it helps to know exactly what those three digits mean. This guide explains the ISO 8573-1:2010 purity classes using the tables SMC and Festo publish in their own documentation, then shows how SMC and Festo combine filters and dryers to reach a target class.
Quick answers
- The three digits are particles : water : oil. [1:4:1] means particle class 1, water class 4 and oil class 1.
- Lower numbers mean cleaner air. Class 0 is not a fixed value. It means a limit set by the equipment user or supplier that is stricter than class 1, so it must always be written out.
- Water class 4 = pressure dew point ≤ +3 °C, which is roughly what a refrigerated dryer delivers. Class 3 (≤ −20 °C) or class 2 (≤ −40 °C) needs membrane or desiccant drying.
- Oil class 1 = total oil ≤ 0.01 mg/m³, counting liquid oil, aerosol and vapour. Coalescing filters alone usually do not get there; oil vapour needs activated carbon.
- Ordinary actuator air does not need a high class. Festo gives 7:4:4 as the purity class for standard pneumatics (valves and cylinders) and 6:4:4 for proportional directional control valves and air tools.
ISO 8573-1:2010 purity class table
The values below are taken from SMC publication P-E26-16, which notes that the classes correspond to JIS B 8392-1:2012. Particle counts are maximum numbers per cubic metre; d is particle size.
| Class | Particles 0.1 < d ≤ 0.5 μm | Particles 0.5 < d ≤ 1.0 μm | Particles 1.0 < d ≤ 5.0 μm | Mass concentration Cp (mg/m³) | Pressure dew point (°C) | Liquid water Cw (g/m³) | Total oil (mg/m³) |
|---|---|---|---|---|---|---|---|
| 0 | As specified by the equipment user or supplier and more stringent than class 1 | ||||||
| 1 | ≤ 20,000 | ≤ 400 | ≤ 10 | — | ≤ −70 | — | ≤ 0.01 |
| 2 | ≤ 400,000 | ≤ 6,000 | ≤ 100 | — | ≤ −40 | — | ≤ 0.1 |
| 3 | — | ≤ 90,000 | ≤ 1,000 | — | ≤ −20 | — | ≤ 1 |
| 4 | — | — | ≤ 10,000 | — | ≤ +3 | — | ≤ 5 |
| 5 | — | — | ≤ 100,000 | — | ≤ +7 | — | — |
| 6 | — | — | — | 0 < Cp ≤ 5 | ≤ +10 | — | — |
| 7 | — | — | — | 5 < Cp ≤ 10 | — | Cw ≤ 0.5 | — |
| 8 | — | — | — | — | — | 0.5 < Cw ≤ 5 | — |
| 9 | — | — | — | — | — | 5 < Cw ≤ 10 | — |
| X | — | — | — | Cp > 10 | — | Cw > 10 | > 5 |
Three details that are easy to miss
- Particle classes 1 to 5 are based on particle counts; classes 6 and 7 switch to mass concentration. A “5 μm filter” and “particle class 5” are therefore not the same thing.
- Water classes 1 to 6 are defined by pressure dew point; classes 7 to 9 by liquid water content. Water class 7 or higher means liquid water is present, which normally means there is no dryer.
- Oil classes stop at 4 (≤ 5 mg/m³). Anything above that is class X.
Decoding [1:4:1]
- Particles, class 1: per cubic metre, no more than 20,000 particles of 0.1–0.5 μm, 400 of 0.5–1.0 μm and 10 of 1.0–5.0 μm.
- Water, class 4: pressure dew point ≤ +3 °C.
- Oil, class 1: total oil content ≤ 0.01 mg/m³.
SMC uses [1:4:1] as the target for its air system solution for optical linear gauges and air seal spindles. Festo lists the same 1:4:1 for air that comes into direct contact with packaging material or with non-dry foods.
What class does an application need?
ISO 8573-1 only defines the classes; it does not say which class a given industry must use. Manufacturer guidance gives useful reference points:
| Use | Class (particles:water:oil) | Source |
|---|---|---|
| Pilot / operating air for standard valves and cylinders | 7:4:4 | Festo white papers |
| Proportional directional control valves, air tools | 6:4:4 | Festo air preparation white paper |
| SMC general recommendation for its products: dry air filtered to 5 μm | equivalent to 6:4:4 | SMC Sweden air preparation catalogue |
| SMC recommended class for general main-line use (AFF + IDF refrigerated dryer + AM) | 2:4:3 | SMC Sweden air preparation catalogue |
| Air-blasting moulds | 5:4:3 | Festo air preparation white paper |
| Direct contact with packaging material or non-dry foods (beverages, meat, vegetables) | 1:4:1 | Festo white papers |
| Direct contact with dry foods or dry products | 1:2:1 | Festo white papers |
Festo states that its application table is based on VDMA 15390-1 and practical experience, that the values are approximate, and that every application must be checked by the operator. Where sterile packaging is required, a sterile filter should be added downstream.
Building up to a class with SMC components
SMC Europe’s “Guide for ISO Quality Air” arranges components in the order coarse particles and water droplets → dehumidification → fine particles and oil mist → oil vapour and odour. The guide lists these ratings:
| Series | Function | Nominal rating / performance |
|---|---|---|
| AF-D air filter | Coarse particle filtration | 5 μm |
| AFF / AFF-D line filter | Coarse particles, water droplet separation | 1 μm, 99 % filtration efficiency |
| AFM-D mist separator | Fine particles, oil mist | 0.3 μm, 99.9 %, oil ≤ 1 mg/m³ |
| AM / AM-D mist separator | Fine particles, oil mist | 0.1 μm, 99 %, oil ≤ 1 mg/m³ |
| AFD-D, AMD / AMD-D micro mist separator | Ultra-fine particles, oil mist | 0.01 μm, 99.9 %, oil ≤ 0.1 mg/m³ |
| AMH-D micro mist separator with pre-filter | Ultra-fine particles, oil mist | 0.01 μm, 99.99 %, oil ≤ 0.1 mg/m³ |
| AMK / AMK-D activated carbon filter | Oil vapour and odour removal | Oil ≤ 0.003 mg/m³ |
| IDFA refrigerated air dryer | Dehumidification | Pressure dew point as low as 3 °C |
| IDG-D membrane air dryer | Dehumidification | Dew point −20 °C (class 3) or −40 °C (class 2) |
Typical paths from the SMC guide
- Main line, no dryer: compressor air taken as [6:8:4] → AFF gives [4:7:4] → adding AM gives [2:7:3] → adding AMD gives [1:7:2]. Water stays at class 7, so liquid water is still present; filters do not replace a dryer.
- Main line with an IDFA refrigerated dryer: water reaches around class 4 (the guide shows [4:4:4] to [4:6:4]); AM and AMD then improve the particle and oil classes, and a final AMK reaches [1:4:1].
- Point of use (inlet taken as [7:4:4]): AF-D gives [6:4:4] and AFF-D gives [5:4:4]; AF-D + AFM-D gives [3:4:3] and AFF-D + AM-D gives [2:4:3]; adding micro mist separation and activated carbon leads to [1:4:2] and [1:4:1]. For water class 2 or 3, an IDG-D membrane dryer is added.
Use the combination diagram in the SMC guide for the exact sequence. SMC also notes that a stated class is the maximum purity class the system can achieve.
Festo configuration notes
- Festo always places a 5 μm filter upstream of its fine and micro filters.
- Festo membrane dryers lower the pressure dew point by about 20 K and require 5 μm and 0.01 μm prefiltration. For a better oil class, put an activated carbon filter downstream of the dryer.
- Adsorption (desiccant) dryers are used when a pressure dew point of −70 °C is required.
- Keep filters inside their specified flow range. Above the maximum flow, contaminants are carried through and the class can no longer be guaranteed; below the minimum flow, separation also suffers.
Festo’s food safety white paper adds two examples: 7:4:4 pilot air can be achieved with a central refrigeration dryer with oil trap plus a 40 μm coarse filter, and an MS6 service unit combination is shown as an example for 1:4:1. Confirm exact module combinations against Festo’s MS series documentation.
How much dew point margin?
Festo recommends a pressure dew point at least 10 K below the lowest ambient (medium) temperature. A refrigeration dryer gives roughly 3 °C, so on its own it suits systems whose operating temperature never drops below 13 °C. Unheated buildings or outdoor pipework in winter need a lower dew point.
Checklist before you specify or order
- Which edition and class does the machine specification require? Does it say ISO 8573-1:2010?
- Are all three digits specified, or only one (for example oil class 1)?
- If class 0 is requested, are the actual limits written down?
- What is the lowest temperature in the plant and along the pipework? Is the dew point at least 10 K below it?
- What is the real peak flow, and do the filter and dryer ratings cover it?
- Is the compressor oil-lubricated or oil-free, and does the oil requirement include vapour?
- Is the air pilot air for valves and cylinders, or process / blast air that touches the product? The two can often be treated on separate branches.
Need help matching components to a class?
Email the target class, pipe size, peak flow, lowest ambient temperature and application to doskee@dustry.ltd and we will help you check the filter and dryer combination. Related reading: building an FRL system with SMC AF/AR/AL and the SMC NMG membrane nitrogen generator, which has its own inlet air requirements. You can also browse our SMC and Festo product categories.
FAQ
Are 1.4.1 and [1:4:1] the same thing?
Yes. Some documents use dots and others colons; the order is always particles, water, oil.
Does an oil-free compressor automatically give oil class 1?
Not necessarily. Festo points out that even with compressors that run without oil, oil aerosols drawn in with the intake air leave a residue. Whether class 1 is met depends on the whole system and on measurement.
If I fit a 0.01 μm filter, do I have particle class 1?
Not on its own. The class depends on inlet air, the full component chain and flow conditions. In SMC’s guide, micro mist separators sit behind upstream filters and dryers, and classes are given for the system as a whole.
Is a higher purity class always better?
No. Stricter classes mean more components, more pressure drop and more maintenance. Pilot air is typically fine at 7:4:4 or 6:4:4; it usually makes more sense to upgrade only the branches that touch the product or feed precision measurement.
Sources: SMC, “Compliant with ISO 8573-1:2010 [1:4:1] Air System Solution for Optical Linear Gauges and Air Seal Spindles” (P-E26-16); SMC Europe, “Guide for ISO Quality Air” (ISO-PURITY-A-CORP-UK); SMC Sweden air preparation catalogue (Luftberedning); Festo white paper “Compressed air preparation in pneumatics” (WhitePaper_Airprep_MS_en.pdf); Festo white paper “Food safety: suitability for use in the food industry through high compressed air quality” (2979_documentation.pdf).