How to Choose an SMC ZK2 Vacuum Unit: Nozzle Size, Energy-Saving Function, and Ejector vs Pump System

2026-11-26 By DoskeeShop 0

When you need a vacuum source for pads and want the generator, valves and a pressure switch in one unit, SMC’s ZK2□A series is the vacuum unit in the official catalogue. It is offered as an ejector system or as a vacuum pump system. On the ejector side, a two-stage design is used; the catalogue states that suction flow is 50% higher than that of other SMC one-stage ejectors. Figures in this article come from the official English catalogue Vacuum Unit ZK2□A Series (CAT.ES100-129C A), checked against the Chinese catalogue ZK2□A.pdf and the SMC web catalogue page for ZK2□A. If a document is revised, the current official file prevails.

The short version

  • Size the nozzle from suction flow and air consumption, not from the diameter figure alone. The four nozzle sizes — 0.7, 1.0, 1.2 and 1.5 mm — differ clearly in maximum suction flow and air consumption. The official web catalogue also gives a guideline pad diameter; that is a starting point, not a substitute for pad calculations.
  • Standard supply pressure is staged by nozzle, and more pressure is not automatically better. With a valve, the supply pressure range is 0.3 to 0.6 MPa. Standard supply pressure is 0.35 MPa for ø0.7 to ø1.2; for ø1.5 it is 0.4 MPa with a valve and 0.37 MPa without. Flow and maximum vacuum pressure in the tables are values at standard supply pressure, under SMC’s measurement conditions, and they vary with atmospheric pressure and the measurement method.
  • Whether the energy-saving function helps depends on whether the set vacuum can be held after pickup. A vacuum pressure switch with the energy-saving function cuts the air supply once the set vacuum is reached. Under SMC’s measurement conditions, the catalogue states a 90% reduction in air consumption for this function, and a 93% energy-saving efficiency when it is combined with the more efficient ejector. Those figures are not a guarantee in every application. If leakage is high, the supply valve will cycle, and the saving should be checked on the actual circuit.
  • Whether vacuum is held after a power cut depends on the supply-valve type — and on whether the air supply is still there. An N.O. supply valve can hold vacuum with the power off and help prevent a workpiece from dropping suddenly, provided the supply pressure is maintained, as the catalogue states. If no plant air is available, an ejector cannot run; see SMC ZXPE5-X3 compact electric vacuum pump for a 24 V unit that does not need compressed air.

What the unit is

The catalogue describes ZK2□A as a vacuum unit for both ejector systems and vacuum pump systems. An ejector system creates vacuum from compressed air. A vacuum pump system does not use the nozzle to generate vacuum; the PV port is connected to a vacuum source (a vacuum pump) in the range 0 to −100 kPa. The unit can integrate a supply valve, a release valve, a vacuum pressure switch or pressure sensor, a silencer and a vacuum filter, which reduces piping and wiring.

The ejector is a two-stage design. With the energy-saving function, air is cut off when the set vacuum is reached and is supplied only intermittently if the vacuum later falls, rather than continuously throughout the hold. Exhaust options are standard silencer exhaust (symbol A), port exhaust (B, single unit) and a high-noise reduction silencer (G). For bags or shrink-wrapped packs with uneven surfaces, the gripper side can be checked separately against SMC ZGS-X7 foam vacuum gripper.

Nozzle size and flow

Maximum suction flow in the table below is the silencer-exhaust / complex-exhaust column; port exhaust and the high-noise reduction silencer give higher suction flow, as listed on catalogue page 29. Air consumption and maximum vacuum pressure are values at standard supply pressure. Pad diameters are guidelines from the official SMC web catalogue, not a guaranteed range.

Model Nozzle (mm) Max. suction flow [L/min (ANR)] Air consumption [L/min (ANR)] Max. vacuum pressure (kPa) Guideline pad (mm)
ZK2□07 0.7 29 24 −91 2 to 40
ZK2□10 1.0 44 40 −91 2 to 50
ZK2□12 1.2 61 58 −91 2 to 125
ZK2□15 1.5 67 90 −91 2 to 150

For a vacuum pump system the nozzle-size symbol is 00 (for example ZK2P00). General specifications: the fluid is air; the operating temperature is −5 to 50°C without a pressure sensor (no condensation) and 0 to 50°C with a pressure sensor; the valve supply pressure range is 0.3 to 0.6 MPa; rated voltage is 24 VDC or 12 VDC; power consumption is 0.4 W. The suction filter is rated 30 µm, with a filtration area of 510 mm². For an ejector system without a valve, the supply pressure range can be 0.1 to 0.6 MPa.

Exhaust type and noise

Symbol A is silencer exhaust: sizes 07 and 10 have no additional exhaust port; sizes 12 and 15 can also exhaust directly from the exhaust port. Symbol B is port exhaust on a single unit. Symbol G is the high-noise reduction silencer. At standard supply pressure, with the vacuum (V) port fully closed and under SMC’s measurement conditions, the catalogue gives these reference noise levels (not guaranteed values): ZK2G 46, 55, 63 and 69 dB(A) for ø0.7 to ø1.5; ZK2A 59, 66, 75 and 76 dB(A). Suction flow also differs: for ø1.5, G is 83 L/min (ANR) and A is 67 L/min (ANR).

Supply valve, release valve, and the energy-saving function

The common valve combinations in the how-to-order tables are: K = N.C. supply + N.C. release; E = N.O. supply + N.C. release; R = self-holding supply valve linked to the release valve (it stays ON after a pulse of 20 ms or more, and opening the release valve turns the supply valve OFF); J = N.C. supply valve only, no release valve. On the how-to-order page for units with the energy-saving function, only K and E are listed. If J is selected, the individual release-pressure (PD) port (option D) and the related release-flow needle options cannot be selected; a release valve or vacuum break valve must be placed in the vacuum piping.

The energy-saving function comes from a vacuum pressure switch with that function: while the suction signal is ON, the supply valve is switched automatically within the set values. The catalogue uses ZK2A12K5KWA-08 as the example part number for the energy-saving comparison: silencer exhaust, 1.2 mm nozzle, valve combination K, 24 VDC, energy-saving switch, V port ø8. The V port is also available as ø6, ø1/4″ or ø5/16″.

Manifold: check how many stations can run at once

On a manifold, the base can have up to 10 stations, but the maximum number that may generate vacuum at the same time still depends on nozzle size and exhaust type. For a PV supply port of ø8 or ø5/16″, with complex exhaust and supply from one side, the limits are 8, 5, 4 and 3 stations for ø0.7, ø1.0, ø1.2 and ø1.5. Supply from both sides, or a change to individual port exhaust or the high-noise reduction silencer, raises those limits; use the catalogue table. If the number of stations generating vacuum at once stays within the table, the manifold can still have up to 10 stations.

FAQ

Will the workpiece drop if power is lost?

For an N.O. supply valve, the catalogue states that vacuum can be held with the power off, provided the supply pressure is maintained, which helps prevent a sudden drop. If the air supply is lost at the same time, that condition is no longer met. The self-holding type (R) is about not needing a continuous signal to the supply valve after a pulse; it is not the same as N.O., and the two should not be mixed up when ordering.

For a leaky workpiece, is a larger nozzle always better?

A larger nozzle raises both suction flow and air consumption. When leakage is high, more suction flow helps hold the vacuum, but air consumption at ø1.5 is 3.75 times that at ø0.7, and fewer manifold stations may run at once. Estimate leakage and response time first, then use the table, rather than defaulting to the largest nozzle.

Can a ZK2 ejector run if there is no compressed air?

An ejector system needs compressed air at the PV port to generate vacuum. If the cell has no plant air, use a 24 V electric vacuum pump or a similar source that does not depend on a shop air line — such as the ZXPE5-X3 above — rather than treating a ZK2 ejector as a plug-in pump.

Always check the current official catalogue when you verify a specification. For a part-number check, send an RFQ to doskee@dustry.ltd.