CPX-FVDA-P2

$742.18

Output Module is a pneumatic component launched by FESTO, which is widely used in the field of industrial automation. Its product quality has been at the leading level in the industry and won the trust and praise of many customers .

Model:CPX-FVDA-P2

FESTO Order Number:1971599

SKU: CPX-FVDA-P2 Category: Tag:

Description

Dimensions W x L x H 50 mm x 107 mm x 55 mm(Incl. linking block and connectors)
Diagnosis Unterspannung VentileDrahtbruch pro KanalKurzschluss/??berlast pro KanalQuerschluss
Parameterising Diagnoseverhalten??berwachung Drahtbruch/Kanal
LED displays 1 Failsafe-Protokoll aktiv1 Sammeldiagnose3 Kanaldiagnose3 Kanalstatus
Intrinsic power input at operating voltage Type 25 mA (operating voltage supply electronics)Type 65 mA (Load voltage supply valve)
Max. power supply per channel 1.5 A
Nominal operating voltage DC [V] 24
Potential separation channel – internal bus Yes, for intermediate feed
Potential separation channel – channel no
Corrosion resistant class KBK (In integrated condition)1 – low corrosion stress
Bearing temperature [??C] -20 to 70
Protection category Depends on connection block
ambient temperature [??C] -5 to 50
Product weight [g] 50,0
Max. address volume outputs [Byte] 6
Max. address volume inputs [Byte] 6
Max. line length 200 m
Material information RoHs compliant
Housing material PCPA reinforced
Fuse (short circuit) Internal electronic fuse Per channel
Quantity outputs: 2
Switching logic outputs PM switching
Safety function Securely switch off the supply voltage of the valves
Safety Integrity Level (SIL) Safe switch off / SIL 3
Performance Level (PL) Safety assembly category 3 performance level e
Load capacity against functional ground [nF] 400
Max. reaction time on switch off command F_WD_TIME + 23 ms
Max. cumulative currents per module [A] 5
residual ripple 2 Vss within voltage range
Voltage drop per channel [V] 0,6
Permitted voltage oscillations -15 % / +20 %
Permission c UL us – Recognized (OL)
CE certificate (see declaration of conformity) to EU machinery directive
Certified awarding point T??V Rheinland 01/205/5294.01/18
Information about ambient temperature Derating-Kurve f??r Pneumatik-Anschaltung beachten
Probability of Failure per Hour in [1/h]. 1e-009
Information about outputs 1 internal channel to switch off valve voltage2 external outputs