Description
Additional functions Spark suppressionHolding current reduction with energy recoveryProtection switch off
Fastening type With throughway boresWith Slot railSelectively:
installation position arbitrary
Product weight [g] 98
Electrical connection 2 pin / 2 pin / 4-wireStraight socket / straight socket / cable
Operating voltage range DC [V] 12 to 53
Reverse polarity protection for operating voltage
Information about operation Power supply must be able to deliver at least 1.85 A without a voltage breakthrough
Information about power consumption Low current phase 2,8 W, High current phase 17,1 W, Per channel
Power-on time 100 %Hinweise zum Betrieb der Magnetventile beachten
Trigger signal range DC [V] 3 to 30
Information about incoming current 0,09 – 0,44 mA bei einem Triggersignal von 3 – 15 V0,44 – 15,44 mA bei einem Triggersignal von 15 – 30 VAnstieg linear
Eingangswiderstand [kOhm] 34
Cable length [MTR] 2,5
Line properties For static applications
Protection category IP40
ambient temperature [??C] -5 to 50
CE certificate (see declaration of conformity) to EU EMC directive
KC-mark KC-EMV
Material information RoHs compliant
Corrosion resistant class KBK 2 – moderate corrosion stress
Cable sleeve material PVC
Housing material POM
Reviews
There are no reviews yet.