CKD SCS2 Large-Bore SELEX Cylinder: Mounting Compatibility with Discontinued SCS, and When to Choose SCS2-G
2026-11-20If a machine still has a discontinued CKD SCS large-bore tie-rod cylinder, or a new design needs a φ125 to φ250 tie-rod cylinder, the successor series is SCS2. This article uses only CKD’s official product pages, the Japanese SCS2 Series catalogue (download file 21710), and CKD Shanghai’s China local-product listing plus the Chinese catalogues CS-CC-1118CS-4 and the SCS2-※-G catalogue CS-CC-945CS-3. If those documents are revised, follow the current official CKD PDFs.
The short answer
- It is a large-bore tie-rod cylinder: bores φ125, φ140, φ160, φ180, φ200 and φ250. Standard strokes are 50, 75, 100, 150, 200, 250 and 300 mm. Catalogue maximum strokes by bore are 800, 800, 800, 900, 1,000 and 1,200 mm. Intermediate strokes can be made in 1 mm increments. The catalogues also list a manufacturable stroke up to 2,000 mm, but they state that exceeding the maximum stroke may mean the product specifications are not met, so confirm with CKD first.
- Weight: the covers and tube are aluminium, and both the product page and the catalogues say the product weight is halved. The supply/exhaust ports and the cushion needle sit on the same face, which makes installation and cushion adjustment easier.
- Mounting versus the old SCS: the catalogues state that mounting dimensions are compatible with the discontinued SCS series (except LH), but the port position has changed. The English product page says the piping port is on the opposite side. The low-hydraulic switch version SCS2-LH is shorter overall than SCS-LH with a switch, so those two are not dimensionally interchangeable; if you need the same length, use the “SCS-LH mounting interchange type” in the catalogue.
- Basic pressure and temperature: for SCS2, SCS2-N and SCS2-LN the fluid is compressed air, maximum working pressure 1.0 MPa, minimum 0.05 MPa, proof pressure 1.6 MPa, ambient temperature −5 to 60°C (no freezing). The lubrication type uses class 1 turbine oil ISO VG32; SCS2-N and LN must not be lubricated. Other variants, such as stroke-adjustable, double-rod or low-hydraulic types, can have a different minimum pressure — check the page for that variant.
Series variants
| Model | Description | Minimum stroke |
|---|---|---|
| SCS2 | Double acting, single rod, lubrication type | 1 mm |
| SCS2-N / SCS2-LN | Double acting, single rod, non-lube (LN with switch) | 1 mm |
| SCS2-P | Double acting, adjustable stroke | 25 mm |
| SCS2-T | Double acting, heat resistant | 1 mm |
| SCS2-D / SCS2-LND | Double acting, double rod (LND non-lube) | 1 mm |
| SCS2-B | Double acting, back-to-back | 1 mm |
| SCS2-W | Double acting, two-stage | 2 mm |
| SCS2-H / SCS2-LH | Double acting, low hydraulic | 20 mm |
| SCS2-G | Double acting, heavy-duty scraper | 1 mm |
All of the variants above use the same six bore sizes. The catalogues also note a more compact T-type switch than the previous series, to reduce protrusion, and that SCS2-LN and SCS2-LH have a magnet as standard, with switch mounting now also available on φ250. Heat-resistant type T is non-lube only, is listed at 120°C in the combination table, and is supplied without a magnet.
Basic specifications for SCS2 / SCS2-N / SCS2-LN
| Item | Value |
|---|---|
| Action / fluid | Double acting / compressed air |
| Max. / min. working pressure, proof pressure | 1.0 MPa / 0.05 MPa / 1.6 MPa |
| Ambient temperature | −5 to 60°C (no freezing) |
| Port size | φ125: Rc 1/2; φ140, φ160, φ180, φ200: Rc 3/4; φ250: Rc 1. NPT and G threads are made-to-order |
| Stroke tolerance | 0 / +1.0 mm up to 300 mm; 0 / +1.4 mm up to 1,000 mm; 0 / +1.8 mm up to 1,200 mm |
| Piston speed | 20 to 1,000 mm/s (stay within the allowable absorbed energy) |
| Cushion / effective cushion length | Air cushion; 21.6 mm for φ125 to φ180, 26.6 mm for φ200 and φ250 |
| Allowable absorbed energy (with cushion) | 63.5, 91.5, 116, 152, 233 and 362 J from φ125 to φ250. Without a cushion the cylinder cannot absorb large energy from an external load; the catalogue recommends an external shock absorber |
Mounting styles include basic (00), axial foot (LB), rod/head flange (FA / FB), single/double clevis (CA / CB), and intermediate or rod/head trunnion (TC / TA / TB). Hole-type trunnions (TF / TD / TE) are made-to-order and, the catalogue says, only for φ125 to φ160.
How to read the model code
Order codes are written left to right: series, mounting, bore, thread, cushion, stroke, then switch model and quantity if required, then options and accessories. For example, SCS2-LB-125B-50 is the lubrication type, axial foot, φ125, Rc thread, cushions both ends, 50 mm stroke; SCS2-LN-LB-125B-50-T0H-R-JY is the non-lube switch type with one T0H reed switch (1 m lead) on the rod end and a rod clevis. Confirm currently orderable codes on CKD’s official model-number page.
- Cushion: B both ends, R rod end, H head end, N none. Option C2 adds a check valve in the cushion and is described as a way to shorten starting time under a large load.
- Thread: blank = Rc; N = NPT and G = G thread, both made-to-order.
- Accessories: I is a single knuckle, Y is a rod clevis (pin and retaining rings included). The catalogue says I and Y cannot be selected together.
Replacing an old SCS, and when to look at SCS2-G
When you check whether an old SCS can be replaced on the same mounting, do not stop at the word “compatible”: the ports have moved to the opposite side, so the existing pipe run may need to be rearranged, and LH with a switch is outside the standard compatibility statement. For long strokes the catalogues also list the ranges that add a mid-span support (for example 1,801 to 2,000 mm on φ125) and the strokes that fall under Class 2 pressure-vessel inspection in the documents (φ160 at 1,948 mm and above, φ180 at 1,526 mm and above, φ200 at 946 mm and above, φ250 at 752 mm and above). Those inspection notes refer to Japanese Ministry of Health, Labour and Welfare ordinances and similar conditions; whether they apply, and how they are handled, must be confirmed under the regulations that govern the actual project.
For stroke-adjustable SCS2-P, the catalogue warns that once the stroke is adjusted, the cushion no longer works. If you are deciding whether to rebuild or replace a leaking cylinder, see Pneumatic cylinder seal kit or new cylinder for a general checklist — do not treat that seal-kit lookup as a substitute for CKD’s own maintenance-parts data for SCS2.
If the rod needs a heavier-duty scraper, look at SCS2-G. CKD Shanghai’s China local-product listing dated 27 October 2026 states that the SCS2-※-G series has entered production in China, and that the rod-end wiper and seal are designed as separate elements for better durability. Pressure, temperature, speed and cushioned absorbed energy for SCS2-G match the basic types above, but the G catalogue requires lubrication with class 1 turbine oil ISO VG32 — do not treat it as a non-lube N / LN cylinder.
What to check before you order
- Whether the bore and stroke fall within the standard strokes or the maximum stroke for that bore; if you go beyond the maximum, confirm with CKD that the specifications can still be met.
- When replacing an old SCS: whether the mounting style matches, whether piping still works after the port moves to the opposite side, and whether the unit is an LH switch type that needs the interchange version.
- Whether supply pressure stays inside the min./max. range for that variant, speed stays within 20 to 1,000 mm/s, and kinetic energy stays within the allowable absorbed energy; and whether an external cushion is needed if you choose no cushion or adjust an SCS2-P stroke.
- Whether the thread is Rc, NPT or G; whether dust or chips point to SCS2-G; and whether a heat-resistant T type is required (no magnet, non-lube only).
- Whether a long stroke enters the mid-span support range or the Class 2 pressure-vessel inspection range listed in the catalogues.
Ask us to cross-check the official documents
Send the existing model or the target bore and stroke, mounting style, thread, cushion arrangement, whether you need a switch or scraper, plus working pressure and speed, and we will check them against the official catalogues: doskee@dustry.ltd.
FAQ
Are SCS2 mounting dimensions exactly the same as the discontinued SCS?
No. The catalogues say mounting dimensions are compatible, but they exclude LH and they state that the port position has changed. SCS2-LH with a switch is also shorter than SCS-LH with a switch; if you need the same length, use the SCS-LH mounting interchange type.
Is the 0.05 MPa minimum working pressure true of every SCS2 variant?
No. 0.05 MPa is the figure in the SCS2, SCS2-N, SCS2-LN and SCS2-G specification tables. In the Chinese catalogue, some other variants are listed at 0.1 MPa minimum. Check the page for the variant you are ordering.
When should I choose SCS2-G?
It is the heavy-duty scraper type, for tougher rod-wiper duty. The China local-product listing highlights the separate rod-end wiper and seal. It is not a non-lube design like SCS2-N.
Sources: CKD “Medium bore size cylinder SCS2” product pages (English, Chinese); CKD “SCS2 Series” Japanese catalogue (PDF); CKD Shanghai China local products listing (SCS2 dated 29 October 2026; SCS2-※-G dated 27 October 2026) and Chinese catalogues CS-CC-1118CS-4 and CS-CC-945CS-3. If the documents are revised, follow the current official CKD catalogues.