How to Choose an SMC IDG Membrane Air Dryer: Dew Point, Flow, and Unit Types
2026-11-24When you need a lower compressed-air dew point than a refrigerated dryer typically provides, and you do not want a separate power supply for the dryer, SMC’s IDG□A/IDG series is the membrane air dryer in the official catalogue. It uses a hollow-fiber membrane to separate water vapor, and the catalogue describes it as needing no power supply, using no fluorocarbons, and producing no vibration or heat discharge, with standard dew points down to −60°C. Figures in this article come from the official English catalogue Membrane Air Dryer IDG□A/IDG Series, checked against the SMC China IDG□A/IDG series page. The separate modular IDG-D series is taken from Chinese catalogue CAT.CS30-23A. If a document is revised, the current official file prevails.
The short version
- Choose the standard dew point first, then size by outlet flow; do not order from the port size alone. If a mist separator is already in the line, the catalogue warns that picking a dryer from the existing port size can yield a model that is too small and lacks dehumidification capacity.
- The catalogue’s standard dew point is the outlet atmospheric-pressure dew point under standard performance conditions. Those conditions are 0.7 MPa inlet pressure and 25°C for inlet temperature, inlet saturation temperature and ambient temperature. It is not a pressure dew point, and it is not a guaranteed value under every duty. If you only have a pressure dew point, convert it with the catalogue chart before you pick a type.
- Size the air supply for outlet flow plus purge flow. Part of the dried air is discharged as purge air. If supply capacity is less than the sum, you will not get the required outlet flow or the intended drying performance.
- A mist separator and a micro-mist separator (or a micro-mist separator with pre-filter) must sit on the inlet; the regulator belongs on the outlet. Oil in the inlet air reduces performance. A regulator on the inlet side reduces dehumidification performance. Unit types already include those separators.
How it dries the air
The catalogue describes hollow fibers made from a membrane that moisture passes through easily, while air (oxygen and nitrogen) does not. When humid compressed air flows inside the fibers, water vapor moves to the outside; a portion of the dry outlet air is then dropped through a small orifice and used to purge the outside of the fibers. Do not obstruct the purge discharge ports: if back pressure rises or purge flow stops, drying performance falls or may stop altogether.
Pick the dew-point type, then the flow
The series covers outlet air flows of 10 to 1000 L/min (ANR) and standard dew points (atmospheric pressure) of −15, −20, −40 and −60°C. Outlet flows below are for the single-unit type under standard performance conditions. Models with an “A” are the reduced-purge IDG□A type in the catalogue.
| Standard dew point | Symbol | Models and outlet air flow, L/min (ANR) |
|---|---|---|
| −20°C | Nil | IDG1: 10; IDG3: 25; IDG5: 50; IDG10: 100; IDG20: 200; IDG30A: 300; IDG50A: 500; IDG60: 600; IDG75: 750; IDG100: 1000 |
| −15°C | H | IDG3H: 25; IDG5H: 50; IDG10H: 100; IDG20H: 200; IDG30HA: 300; IDG50HA: 500; IDG60H: 600; IDG75H: 750; IDG100H: 1000 |
| −40°C | L | IDG30LA: 75; IDG50LA: 110; IDG60LA: 170; IDG75LA: 240; IDG100LA: 300 |
| −60°C | S | IDG60SA: 50; IDG75SA: 100; IDG100SA: 150 |
At the same body size, a lower standard dew point means a smaller outlet flow under the rated conditions. Size 100, for example, is 1000 L/min (ANR) in the −20°C type and only 150 L/min (ANR) in the −60°C type. Type L starts at size 30; type S starts at size 60; IDG1 is offered only in the −20°C type. If you also need to read pressure dew point or ISO particle/water/oil classes, see our earlier guide to ISO 8573-1 compressed air quality classes.
Single unit or pre-assembled unit
- Single unit: the membrane dryer only. You must add a mist separator and a micro-mist separator on the inlet yourself.
- Type M: a mist separator, a micro-mist separator (or one with a pre-filter), and the membrane dryer, already modularly connected.
- Type V: type M plus a regulator. When highly purified air is required, the catalogue recommends a micro-mist or super-mist separator on the outlet; grease is applied inside the type-V regulator, so for that duty follow the catalogue and add an outlet separator or use the corresponding made-to-order version.
Under the same standard dew point and size, unit types have the same rated outlet flows as the table above. Liquid water must still be kept out of the inlet, whether or not you choose a unit type; for moisture in the air line, see how moisture in compressed air affects a pneumatic system. Air-preparation combinations are also discussed in our FRL air-prep article, and related SMC components are listed under the SMC category. Specifications still come from the official catalogue.
How to read the model code
Take the catalogue ordering example IDG30HAM4-03: IDG series, size 30, H for a −15°C standard dew point, A for the reduced-purge IDG□A type, M for a unit type (separators included, no regulator), 4 for modular connection, and 03 for Rc 3/8. Port thread is Rc if blank, N for NPT, F for G. Among semi-standard options, P adds a fitting for purge-air discharge and R reverses the flow direction to right-to-left; if you use more than one, list them alphabetically. Unit types also have a drain-discharge symbol: blank for a manual valve, C for an N.C. auto-drain, D for an N.O. auto-drain, and J for a drain guide. If the compressor is 2.2 kW (300 L/min [ANR]) or less, the catalogue specifies an N.C. auto-drain (C), not an N.O. type (D), otherwise pressure in the mist separator may not build and the drain may stay open.
Operating limits differ by size
The fluid is compressed air in every case. Inlet pressure and temperature are grouped by model, so do not apply one range to the whole series:
- IDG1 to IDG20 and the matching H types: inlet pressure 0.3 to 0.85 MPa; inlet and ambient temperature −5 to 55°C (no freezing).
- IDG30A/50A and IDG60/75/100, plus the matching H, L and S types: inlet pressure 0.3 to 1.0 MPa; inlet and ambient temperature −5 to 50°C (no freezing).
The standard performance tables also list inlet, outlet and purge flows at 0.7 MPa and 25°C. The purge flow includes 1 L/min (ANR) for the dew-point indicator at 0.7 MPa inlet pressure, except IDG1, IDG3 and IDG5 on the −20°C table and IDG3H and IDG5H on the −15°C table. Larger models have a dew-point indicator as standard; its color shows whether the outlet air is dry or wet (blue/pink or green/yellow, depending on the absorbent). The color change takes time, and vaporized oil or other gases can shift it to another color.
Selection and installation points that are easy to miss
- If the inlet temperature is not 25°C, correct the outlet flow before you select a model. The catalogue’s model-selection steps divide the required outlet flow by an inlet-temperature correction factor; the IDG□A factors are not the same as those for the non-A IDG series. In the catalogue example at 35°C, the factor is 0.86 for IDG□A and 0.40 for the IDG series. Then add that model’s purge flow and check the air-supply capacity.
- It takes time to reach the standard dew point. After air starts flowing, allow about 10 minutes for −20°C/−15°C, about 30 minutes for −40°C, and about 60 minutes for −60°C before you start the downstream equipment. For the two lower dew points, the catalogue describes a shorter method: close the outlet valve and let only purge air flow for 15 minutes or more, then open the valve.
- Do not block the purge discharge, and plan where that wet air goes. Purge air is humid; keep it from corroding or disturbing nearby equipment. For option P, use the specified tube size and keep the length within 5 m; a longer tube reduces drying capacity. P cannot be combined with a manual drain (blank symbol) or with type V.
- For dew points of −40°C or lower, do not use nylon tube or ordinary resin fittings on the outlet. The catalogue specifies stainless steel or fluoropolymer tube and fittings; otherwise the prescribed low dew point may not be reached at the end of the line. Purge and indicator piping may be combined, but must not be teed into the main compressed-air line, drain piping, or exhaust from other equipment.
- Do not apply intermittent pressure to the dryer. A frequently cycling solenoid valve on the inlet side is the catalogue’s example of a condition that can damage the product. Keep the inlet air temperature lower than ambient temperature; if the body is cooled by the surrounding air, water can collect inside and reduce capacity. If you install the dryer immediately after a reciprocating compressor, confirm that the fluid temperature stays within the operating range.
- Do not use the −40°C (L) or −60°C (S) types, or IDG30A, IDG50A, IDG30HA and IDG50HA, to dry breathing air; and do not use outlet air alone in a closed room. Depending on the model and conditions, the oxygen ratio of the outlet air may drop.
Do not mix the modular IDG-D tables with the series above
SMC also offers the modular IDG-D series (Chinese catalogue CAT.CS30-23A). Sizes 20, 30 and 40 mate with AC20, AC30 and AC40 modules, with rated outlet flows of 100, 250 and 500 L/min (ANR) under that catalogue’s standard conditions. IDG-D states results in ISO 8573-1 moisture classes that vary with flow. Its operating range is −5 to 50°C (no freezing) for ambient and fluid temperature, with a proof pressure of 1.5 MPa, a maximum operating pressure of 1.0 MPa and a minimum of 0.3 MPa. Inlet air quality is given as an ISO 8573-1:2010 class in that catalogue. Do not apply the IDG□A/IDG atmospheric-dew-point table to IDG-D, or the other way around. For how to read moisture classes, see ISO 8573-1 compressed air quality classes.
Checklist before you order
- You know whether the target is an atmospheric or a pressure dew point, and which of −15/−20/−40/−60°C applies.
- Required outlet flow has been corrected for inlet temperature, purge flow has been added, and the sum is still within the air-supply capacity.
- Single unit versus type M or V is decided, inlet filtration matches the catalogue, and any regulator is on the outlet.
- Port thread (Rc/NPT/G), flow direction, purge fitting and auto-drain type match the compressor capacity.
- Outlet piping materials are suitable for a low dew point, and purge air will not be blocked or directed at nearby equipment.
- If you are looking at IDG-D, it is sized from CAT.CS30-23A on its own, not from the IDG□A/IDG flow table.
Ask us to check a model
Send the required outlet flow, the dew point (and whether it is atmospheric or pressurized), inlet pressure and temperature, whether filters or a regulator are already in the line, and whether you want a single unit or a pre-assembled unit, and we will check it against the official catalogue. Email doskee@dustry.ltd.
FAQ
Why add a membrane dryer after a refrigerated dryer?
A refrigerated dryer is typically sized around a pressure dew point of about 3 to 10°C. When a lower, stable atmospheric dew point is required, SMC’s refrigerated-dryer catalogue also points to the IDG series. A membrane dryer needs no power supply and has no refrigerant or heat discharge, but it does consume purge air, so the supply must cover outlet flow plus purge. The dew-point definition, rated conditions and correction methods are not the same, so do not treat a refrigerated dryer’s pressure-dew-point figure as an IDG standard dew point.
Why is one size-50 model rated at 500 L/min and another at only 110?
That is the dew-point type, not a typo in the size. IDG50A and IDG50HA are the −20°C and −15°C types, with a rated outlet flow of 500 L/min (ANR); IDG50LA is the −40°C type, with 110 L/min (ANR) under the same standard conditions. Size 50 has no S type (−60°C). Check both the dew-point column and the flow column before you order.
We already have filters. Do we still have to size by flow?
Yes. The catalogue says that selecting a membrane dryer from the port size of equipment already installed can result in a model that is too small and has insufficient dehumidification capacity. Confirm the actual operating flow and pressure, then follow the model-selection steps, including the inlet-temperature correction and purge air.
Sources: SMC English catalogue Membrane Air Dryer IDG□A/IDG Series (PDF, including series variations, how to order, standard specifications, model selection and specific product precautions); SMC Chinese catalogue 高分子膜式空气干燥器 IDG□A/IDG (PDF); SMC China web catalogue page “Membrane air dryer IDG□A/IDG” (IDG-ZH); for the modular series, Chinese catalogue IDG-D CAT.CS30-23A (PDF, including basic specifications and ISO 8573-1 moisture-class notes). If a document is revised, the current official SMC catalogue prevails.