When you add a tank after an SMC booster regulator, the series you will usually meet is VBAT. Two details are easy to mix up. The size code “20” is not always 20 L, and the suffixes X104 and X105 are not the same pressure-vessel approval. This article uses only SMC’s official VBA/VBAT catalogues and the VBAF booster catalogue CAT.ES11-124. If a figure is revised, follow the current SMC PDF.

The short answer

  • VBAT is a compact air tank meant to mount with a booster regulator, and it can also be used on its own. The catalogues offer carbon steel (A / A1, SS400 or equivalent) and stainless steel (S / S1, 304 or equivalent), each in four capacities.
  • Do not mix the three specification families. The standard product for the Japanese market is 5, 10, 20 and 38 L. The Chinese pressure-vessel version (VBAT-X104) and the ASME / CRN version (VBAT-X105) are 5, 10, 22 and 38 L, so the code “20” means 22 L on those two families.
  • Maximum operating pressure also changes by family. X104: 1.5 MPa on 5 L and 10 L, 1.0 MPa on 22 L and 38 L. Standard Japanese-market carbon-steel tanks: 2.0 MPa on 5 L and 10 L, 1.0 MPa on 20 L and 38 L; all four stainless standard sizes are 2.0 MPa. All four X105 sizes are 2.0 MPa.
  • A booster can be mounted directly on the tank only when the pairing appears in the official compatibility chart. The VBA chart and the VBAF chart are not the same.

Match the regulation and the capacity first

Family Suffix / scope Capacity for codes 05 / 10 / 20 / 38 Max. operating pressure
Standard product (Japanese market) e.g. VBAT10A1 5, 10, 20, 38 L Carbon steel: 2.0 MPa (5 / 10 L), 1.0 MPa (20 / 38 L); stainless steel: 2.0 MPa on all four
Chinese pressure vessel regulations -X104 5, 10, 22, 38 L 1.5 MPa (5 / 10 L), 1.0 MPa (22 / 38 L)
ASME / CRN (United States and Canada) -X105 5, 10, 22, 38 L 2.0 MPa on all four

The X104 pages cite Chinese safety technical specification TSG R0003-2007 for simple pressure vessels, and the tank is supplied with a safety-valve / pressure-gauge set and product certificates. X105 is the ASME / CRN product for the U.S. and Canada; the catalogue states that it can only be purchased from SMC Corporation of America. Other regional versions, such as CE/UKCA and Korean occupational-safety variants, are listed with capacities of 5, 10, 20 and 38 L (here 20 means 20 L). Use the official overseas table for those options.

The Japanese-market how-to-order page also states that the standard product is not classified as a Class 2 pressure vessel. That wording belongs to that family only; do not copy it onto X104 or X105. If a standard tank is used alone (not connected to a booster) and pressurised above 1 MPa at normal temperatures, the same catalogue says it falls under Japan’s High Pressure Gas Safety Act. For other countries, follow the rules that apply at the installation site.

How to read an X104 model, and the basic specifications

An X104 order code reads, from left to right: VBAT, capacity code, material, safety-valve / gauge set, then X104. For example, VBAT10A1-U-X104 is a 10 L carbon-steel tank with the U set; VBAT20S1-T-X104 is a 22 L stainless-steel tank with the T set.

  • Capacity codes: 05 = 5 L, 10 = 10 L, 20 = 22 L, 38 = 38 L.
  • Material: A1 is carbon steel (equivalent to SS400); S1 is stainless steel (equivalent to 304).
  • Safety valve / pressure gauge set: U is for sizes 05 and 10; T is for sizes 20 and 38, in both materials. If a drain valve is required, order VBAT-V1 separately. The catalogue notes that the safety-valve / gauge set is not RoHS compliant.
Item VBAT05□1-U-X104 VBAT10□1-U-X104 VBAT20□1-T-X104 VBAT38□1-T-X104
Tank capacity 5 L 10 L 22 L 38 L
Max. operating pressure 1.5 MPa 1.0 MPa
IN port size 3/8 1/2
OUT port size 3/8 1/2 1/2 3/4
Proof pressure (carbon steel A1) 2.39 MPa 2.05 MPa
Proof pressure (stainless S1) 2.40 MPa 1.58 MPa
Ambient and fluid temperature 0 to 75 °C
Installation Horizontal (floor mounting)
Weight (carbon steel A1) 6.6 kg 11.5 kg 14 kg 26 kg
Weight (stainless S1) 4.6 kg 8.5 kg 13.9 kg 19.6 kg

The fluid is compressed air. Included parts are the safety-valve / pressure-gauge set (valve, gauge and connecting piping), plus an O-ring, drain-port plug, VBA connection screws (4 pcs), anchor bolts and nuts (4 pcs, 22 L and 38 L only), product certificates and the operation manual. The catalogue states that product certificates are required when exporting to and using the product in China, and that they should be kept in a safe place. How those certificates are handled on site is a matter for the local authority.

Carbon-steel tanks may rust. SMC recommends an air filter (AF series) on the OUT port; if rust would be a problem, choose the stainless-steel version. X105 figures are different from the table above (maximum operating pressure 2.0 MPa and proof pressure 2.2 MPa on all four sizes), and that catalogue also says the tank cannot be mounted to walls or ceilings. Do not reuse X104 numbers on an X105 tank.

Direct mounting with VBA and VBAF

The catalogues say a booster can be connected compactly to the tank, but only in the combinations shown. For the VBA series (standard-product chart):

Air tank VBA1□A (e.g. VBA10A / 11A) VBA2□A (e.g. VBA20A / 22A) VBA4□A (e.g. VBA40A / 42A / 43A)
VBAT05A / VBAT05S Direct mount — —
VBAT10A / VBAT10S Direct mount Direct mount —
VBAT20A / VBAT20S — Direct mount Direct mount
VBAT38A / VBAT38S — Direct mount Direct mount

The newer VBAF series differs from VBA mainly by its fixed boost ratio and the absence of a regulator knob. The VBAF catalogue says the booster can be installed directly on existing VBAT tanks, but the pairing table is not identical to VBA:

Air tank VBAF10-02 / VBAF11-02 VBAF20-03 VBAF21-03
VBAT05A1 / VBAT05S1 Yes — —
VBAT10A1 / VBAT10S1 Yes Yes Yes
VBAT20A1 — Yes —
VBAT20S1 — Yes Yes
VBAT38A1 — Yes —
VBAT38S1 — Yes Yes

The 4× booster VBAF21 does not pair with carbon-steel VBAT20A1 or VBAT38A1. It does pair with VBAT10 in either material, and with stainless VBAT20S1 and VBAT38S1. Order the booster separately. For a short description of a 5 L ASME example and a 5 L Chinese-regulation stainless example already on this site, see VBAT05A1-EV-X105 and VBAT05S1-U-X104. Those pages are older product introductions; use the official catalogues cited below for specifications and approvals, and do not mix suffix explanations.

Points the catalogues emphasise for installation and maintenance

  • Stay at or below the maximum operating pressure. If the tank is used alone, fit a pressure switch and a safety valve, and do not operate above the rated maximum.
  • Fit a filter or mist separator on the tank OUT port. The Japanese-market standard pages note that the inner surface is not treated, so dust may leave through the outlet.
  • Mount the tank horizontally on the floor. When floor-mounted, all four mounting holes must be secured with screws or anchor bolts. The X105 catalogue also says the tank cannot be mounted to walls or ceilings.
  • Drain condensate once a day. Residual condensate can cause malfunction and can corrode the inside of the tank.
  • Install the tank away from areas where people work. Air stored in the tank is dangerous if it is released suddenly. Do not mount the tank on moving parts or where it will be exposed to vibration.

Selection checklist

  • Which approval applies at the site: X104 for use in China, X105 for the U.S. and Canada, and the CE or other regional variants elsewhere. Do not order from the capacity number alone.
  • Read the capacity code correctly: “20” is 22 L on X104 and X105, and 20 L on the Japanese-market standard product and some overseas variants.
  • Confirm that the working pressure stays within that family’s maximum. On X104, the 5 L and 10 L tanks are 1.5 MPa, not the 2.0 MPa figure used on standard carbon-steel tanks of the same size.
  • Choose carbon steel or stainless steel; check the OUT port and thread; add drain valve VBAT-V1 only if you need it.
  • Check that the booster you plan to use appears in the direct-mount table. The VBA and VBAF tables differ, especially for VBAF21 with carbon-steel 22 L and 38 L tanks.

Ask us to check a combination

Send the destination country, the capacity you need, material, port thread, and the booster model you plan to mount. We will check it against the official catalogues. Email doskee@dustry.ltd.

FAQ

Is VBAT20 a 20-litre tank?

Not always. On the Japanese-market standard product and on some CE-type variants, code 20 is 20 L. On VBAT-X104 and VBAT-X105, code 20 is 22 L. Check the suffix before you order.

Is X104 an ASME tank?

No. X104 is the Chinese pressure-vessel version. The ASME / CRN product uses the suffix X105. Capacities are also 5, 10, 22 and 38 L, but the maximum operating pressure, proof pressure and weights are not the same as X104.

Can every VBAF model mount directly on every VBAT tank?

No. The VBAF catalogue allows direct installation on existing VBAT tanks only in the combinations shown. VBAF10 and VBAF11 do not pair with the 22 L or 38 L tanks, and VBAF21 does not pair with carbon-steel VBAT20A1 or VBAT38A1.

Sources: SMC Booster Regulator / Air Tank VBA/VBAT English catalogue (PDF, including the standard, X104 and X105 specification pages); SMC Chinese VBA/VBAT catalogue (PDF); SMC VBAF catalogue CAT.ES11-124 (PDF, tank compatibility table). If a document is revised, the current official SMC catalogue prevails.