AVENTICS XV05 High Flow vs Standard XV05: When 1,200 L/min Means You Can Stay on the Same Valve Platform

2026-11-18 By DoskeeShop 0

When a valve manifold runs out of flow, the usual next step is a larger platform — and with it, new interfaces, new wiring and a reworked pneumatic layout. In the second half of 2026 Emerson introduced the AVENTICS XV05 High Flow as an extension of the existing XV platform. The product announcement states a maximum flow of 1,200 L/min, compared with 1,000 L/min for the standard XV05, and says High Flow and standard modules can share the same valve system. This article uses only the official operating instructions 570365-BAL Rev.AE (January 2026), the official XV brochure FL000712ZHCN-03 (February 2026), and Emerson’s High Flow product announcement as carried in the trade press in September–October 2026. The announcement does not republish pressure, temperature or other ratings for the High Flow variant; check those against the current official catalogue and the XV online configurator.

The short version

  • Standard XV05: the current official instructions list a maximum flow of 1,000 l/min; the brochure lists 1,000 NL/min. The nominal orifice is 6 mm. The related XV03 is 4 mm, with a maximum of 350 l/min / 350 NL/min.
  • XV05 High Flow: Emerson’s announcement puts the maximum at 1,200 L/min. The extra airflow comes from larger ports and dedicated high-flow fittings, used only where the application needs them.
  • You do not have to move to a larger platform: the announcement states that High Flow keeps the same architecture, electrical connection options, communication protocols and modularity as the standard XV05, and that the two module types can be combined. Porting is front, top or bottom.
  • One caveat: Emerson’s 3 July 2024 launch release, written before XV05 was on the market, quoted up to 880 NL/min. The current instructions and brochure use 1,000. This article follows the current documents.

Standard XV05 vs High Flow

Figures for the standard XV05 come from the instructions and the brochure. The High Flow column includes only what the announcement states; ratings it does not give are not inferred here.

Item Standard XV05 XV05 High Flow
Role The higher-flow size in the XV series A high-flow extension of the same platform, so a larger valve family is not required for this step-up in flow
Maximum flow 1,000 l/min in the instructions; 1,000 NL/min in the brochure Up to 1,200 L/min (announcement)
Ports Outputs 2 and 4: Ø 4 mm to 8 mm; universal thread (BSPP and NPT combined, for push-in fittings) Larger ports and dedicated high-flow fittings (announcement; confirm sizes in the current official documents)
Port positions Brochure: front, bottom or top Announcement: front-, top- and bottom-ported
Mixing modules — Announcement: High Flow and standard XV05 modules can be combined in one valve system
Electrical, protocols, modularity See the next section Announcement: the same as the existing XV platform
Nominal orifice 6 mm Not stated separately in the announcement

Standard XV05: key data from the instructions

The following is taken from the technical data in 570365-BAL Rev.AE for the XV03 / XV05 valve system covered by that document. The High Flow announcement does not repeat these values, so they should not be read as High Flow ratings.

  • Temperature: ambient and medium −10 to +50 °C; storage −25 to +70 °C. Degree of protection IP65 (EN 60529 / IEC 529). Relative humidity 95%, non-condensing. Seal materials NBR and HNBR.
  • Electrical: 24 V DC ±10%; power consumption 0.6 W (1.2 W when switching). Control, depending on the configuration, is single wiring, parallel wiring via D-Sub, or a bus coupler. With a bus coupler the product can control up to 48 solenoid coils and up to 24 valves; with a D-Sub multipole plug, up to 42 solenoid coils and up to 42 valves.
  • Pressure: external pilot air −0.9 to +8 bar; internal pilot air +3 to +8 bar; pilot air +3 to +8 bar. Permissible exhaust air noise is max. 85 dB. Mounting orientation is any; mounting may be on a plate, on a DIN rail, or in a control cabinet.
  • Compressed air: compressed air only, non-condensing, maximum particle size 40 μm, oil content 0 to 5 mg/m³. The pressure dew point must be at least 15 °C below the ambient or medium temperature, and at most 3 °C. For how purity classes are written, see ISO 8573-1 compressed air quality classes explained.

The brochure adds that supported protocols include PROFINET, EtherNet/IP, EtherCAT, Powerlink, Modbus TCP, IO-Link, AS-Interface, CANopen and Profibus, and that parallel wiring can use a D-SUB 25/44-pin connector or a terminal strip. Accessory options include pressure regulators, shut-off valves, speed-control / throttle modules, and supply / exhaust modules. The official online configurator can be used for system layout, accessory selection and generating an order code.

How to choose, and what to check before you order

  • Start with the standard XV05 if the required flow stays within the 1,000 l/min given in the current instructions (1,000 NL/min in the brochure), the existing XV electrical and communications setup is sufficient, and you do not need larger ports on individual stations.
  • Consider mixing High Flow modules on the same manifold if only some stations need more flow and you want to avoid moving the whole machine to a larger platform. The announcement states that the larger ports and dedicated fittings are used where needed, and that High Flow and standard modules can be combined.
  • Confirm against the current official documents for anything the announcement does not list: High Flow pressure and temperature ratings, port sizes, and coil or valve limits, as well as thread type, port orientation, piloting, fieldbus protocol and accessories. Typical applications named in the announcement include pilot systems for process valves in water treatment, package moulding, slicing and cutting that needs high actuator force, cleaning systems, pneumatically driven winches in oil and gas, and automotive equipment with high airflow demand — whether they fit your machine still depends on the actual flow and the space you have.

Request a review

Send us the required flow, number of valve stations, electrical connection (single wiring, D-Sub or fieldbus protocol), port orientation and thread type, and we will help you check them against the official documents: doskee@dustry.ltd. Related reading: ISO 8573-1 compressed air quality classes explained. You can also browse the AVENTICS product category.

FAQ

Can High Flow and standard XV05 modules share one valve system?

Yes. Emerson’s announcement states that High Flow is compatible with the standard XV05 and that the two module types can be combined in a single valve system, with High Flow used only where the extra flow is needed.

Why do some pages still quote 880 NL/min?

That figure appeared in Emerson’s 3 July 2024 launch release, when XV05 was still scheduled for October 2024. The January 2026 operating instructions list 1,000 l/min, and the February 2026 brochure lists 1,000 NL/min. This article follows the current official documents; always check the current PDF.

If you need 1,200 L/min, do you have to change to a larger valve platform?

Not necessarily, according to the announcement. XV05 High Flow is intended to raise flow to 1,200 L/min on the existing XV platform, keeping the same architecture, electrical connections and communication protocols. If flow, pressure or other ratings fall outside the current official documents, look at other platforms and verify them against the official catalogue.

Sources: AVENTICS XV03 / XV05 Operating instructions 570365-BAL Rev.AE, January 2026 (570365.pdf); AVENTICS XV valve system brochure FL000712ZHCN-03_02-26 (aventics-xv-valve-system-v20.pdf); Emerson, “New Emerson Pneumatic Valves Provide Greater Automation Flexibility, Optimized Flow,” 3 July 2024 (official release); Emerson, “Expands AVENTICS XV Platform to Address Growing Demand for Higher Airflow in Automation,” as carried in the trade press (e.g. Hydrocarbon Processing, 15 October 2026 and Engineer Live, 25 September 2026). If the documents are revised, the current official catalogue and configurator take precedence.