How to Choose an SMC AFF, AM or AMD Compressed Air Filter: Filtration Rating, Flow, and ISO 8573 Purity Class

2026-11-28 By DoskeeShop 0

When compressed air needs dust, water droplets and oil mist taken out before it reaches valves and cylinders, SMC’s modular AFF, AM and AMD filters are often specified together. They share the same body sizes (20 to 60) and the same port-size steps, but they do not share the same filtration rating or the ISO 8573 purity class stated in the catalogue. The figures below are taken from SMC catalogue CAT.CS30-22D, Modular Connection Type Compressed Air Preparation Filter, AFF/AM/AMD/AMK Series. This article covers only the current -D series (AFF20-D to AFF60-D and the matching AM and AMD bodies). It does not mix in ratings from earlier typenumbers such as AFF□C or AM□C.

What each series is for

The catalogue describes AFF as a line filter for coarse dust and water-droplet separation; AM as a mist separator for dust and oil mist; and AMD as a micro mist separator, also for dust and oil mist but at a finer rating. Because the maximum processing flow and port options are the same at a given body size, the units can be modularly connected as shown in the catalogue.

The same catalogue also lists the AMK activated carbon filter, which adsorbs oil vapor and helps reduce odor. A stated precaution is that an AMD must be installed upstream of an AMK to avoid a drop in performance. AMK is not the focus of this selection guide; check the catalogue for its inlet conditions and element life if odor removal is required.

The catalogue also notes that, when the product is used within its specifications, a single AFF can remove water droplets and solid particles, so a separate water separator (AMG series) is not required under that condition. That is not a licence to skip a dryer when the inlet air carries a large amount of condensate: the precautions say to install a refrigerated air dryer or aftercooler on the inlet side, otherwise performance will fall. Removing already-condensed droplets is not the same as lowering the pressure dew point. For dew-point steps, see How to choose an SMC IDG membrane air dryer; for how to read the three ISO 8573 digits, see ISO 8573-1 compressed air quality classes.

How the standard specifications compare

The table below is from the standard specifications. The fluid is compressed air. Ambient and fluid temperature is −5 to 60°C (no freezing). Proof pressure is 1.5 MPa; maximum operating pressure 1.0 MPa; minimum operating pressure 0.05 MPa. Maximum processing flow is given at 0.7 MPa inlet pressure, 20°C, atmospheric pressure and 65% relative humidity. The flow curves add this warning: if the actual flow exceeds the maximum processing flow, the specifications may not be met.

Series Catalogue function Filtration rating (efficiency) Water droplets or outlet oil mist Stated purity class (ISO 8573-1:2010)
AFF Coarse dust filtration and water-droplet separation 1 μm (99%) 99% water-droplet removal [4:7:4] (when the inlet class is [6:8:4])
AM Dust filtration and oil-mist separation 0.1 μm (99%) Outlet oil mist 1 mg/m³ (0.8 ppm) or less [2:7:3] (when the inlet class is [4:7:4])
AMD Dust filtration and oil-mist separation 0.01 μm (99.9%) Outlet oil mist 0.1 mg/m³ (0.08 ppm) or less [1:7:2] (when the inlet class is [2:7:3])

Each rating is tied to a test condition and to a new element. AFF’s 99% droplet removal is measured at an inlet droplet load of 33 g/m³, 25°C inlet temperature, and stable flow and pressure; “droplets” here means condensed water, not uncondensed vapor. AM’s outlet oil-mist figure is measured with 10 mg/m³ oil mist at the inlet; AMD’s is measured with 1 mg/m³ at the inlet, and the catalogue also states an initial value of 0.01 mg/m³ (0.008 ppm) or less. The AM and AMD pages note that a small amount of grease is used on the bowl seal and other O-rings.

The purity classes are likewise conditional. In the catalogue’s system example, air entering at [6:8:4] is shown as [4:7:4] after AFF, [2:7:3] after AM, and [1:7:2] after AMD — described as the highest class that system can achieve. In that example the moisture class stays at 7; adding these filters does not by itself move the dew-point class to 4 or 1. If a specification calls for a lower pressure dew point, a dryer has to be sized as well.

Body size, port size and how the part number is built

Choose the body size from the required flow first, then the series and the port. The catalogue warns that the instantaneous maximum of the output flow must not exceed the maximum processing flow.

Body size Port size Max. processing flow L/min (ANR) Weight (kg) Bowl material
20 1/8, 1/4 300 0.19 Polycarbonate
30 1/4, 3/8 750 0.39 Polycarbonate
40 1/4, 3/8, 1/2 1500 0.79 Polycarbonate
50 3/4, 1 2200 1.23 Stainless steel
60 1 3700 1.46 Stainless steel

Sizes 20 to 40 use a polycarbonate bowl as standard (metal or nylon bowls are listed as made-to-order options). Sizes 50 and 60 use a stainless-steel bowl as standard. For a normally closed (N.C.) auto drain, the minimum operating pressure is 0.1 MPa on size 20 and 0.15 MPa on sizes 30 to 60. A normally open (N.O.) auto drain is not available on size 20; on sizes 30 to 60 its minimum operating pressure is 0.1 MPa. The N.O. drain also requires a compressor of at least 0.75 kW and 100 L/min (ANR) — scale that capacity by the number of drains — and an operating pressure of 0.1 MPa or more, or the drain may not work correctly.

The part number is built as: series (AFF / AM / AMD) + body size + thread (blank = Rc, N = NPT, F = G) + port size + options/semi-standard codes, ending in D for this series. Option letters are written in ascending number-then-letter order. For example, AFF30-03BD-D is an AFF, body size 30, Rc 3/8, with bracket and an N.O. auto drain. The catalogue also shows AM30-N03BD-6RZ-D as an example of stacked option codes. Element colour is a further check: grey for AFF, light blue for AM, and blue for AMD.

Installation and element life

Connect the piping only after checking the “1” and “2” marks or the flow arrows; reverse connection will not work. Mount the unit vertically with the drain outlet facing down — not sideways or upside down. Do not operate with a pressure drop greater than 0.1 MPa between inlet and outlet (including pulsation); the element can be damaged. Polycarbonate bowls must not be used where the catalogue lists organic solvents, acids, alkalis or ester compressor oils, among other fluids; if in doubt, the catalogue recommends a metal bowl.

Replace the element on AFF20–60-D, AM20–60-D and AMD20–60-D within two years from the start of use, or before the product pressure drop (outlet versus inlet) reaches 0.1 MPa — otherwise the element can be damaged. If a clogging switch is fitted and it detects clogging, replace the element even if two years have not yet passed. AMK has a shorter interval: within one year or 2000 hours of use, and also whenever an oil odor appears on the outlet side.

FAQ

Can an AFF alone reach oil class 1?

Not in the catalogue’s system example. With an inlet of [6:8:4], AFF is shown as [4:7:4], so the oil class is still 4. Reaching oil class 3 or 2 in that example requires AM and then AMD, and only under the inlet conditions the catalogue states. Do not infer a class from the series name alone.

Why does the moisture class stay at 7 in the example?

AFF removes condensed droplets, which the catalogue distinguishes from uncondensed water vapor. Pressure dew point is a different moisture metric and needs a dryer to change it. If a specification asks for something like [1:4:1], size both the filter chain and the drying method; a finer filter grade is not enough by itself.

Can an older AM150C or AFF4C be mixed on the same modular interface as a new -D unit?

The catalogue only compares AFF□C, AM□C and AMD□C as previous products for weight and envelope. It does not state that old and new typenumbers share the same modular interface. Check mounting, flow and accessories against the current official catalogue before replacing a unit, and do not apply older filtration ratings (such as 3 μm or 0.3 μm found in earlier literature) to the -D series.

Always confirm specifications against the current official catalogue: CAT.CS30-22D (PDF) and the official series page for AFF/AM/AMD/AMK. For a part-number check or an RFQ, email doskee@dustry.ltd.